Firestop Contractors - Hilti Firestop Specialty Contractors

Firestop Contractors

Firestop Contractors

Find a Firestop Contractor

Become a Hilti Accredited FSC

Specify Hilti Firestop

Click on any of the links below to download Hilti firestop specifications:

Section 07840 - Firestopping Section 07841 - Firestop (Pens) Section 07842 - Firestop (Joints)
 

Curtain Wall Firestop Systems Details

[« Return to Firestop Systems Home]

UL / Trade Detail Description F-Rating Product(s)
CEJ127P_110610.pdf Glass Spandrel Panel with Aluminum Framing (Max JW = 6") 2-hour CP 672 FC
CFS-SP WB
CEJ216P_021312.pdf Glass Spandrel Panel and Aluminum Framing (Max. JW=6") 2-hour CP 672 FC
CFS-SP WB
CEJ244P_021312.pdf Concrete Panels with Steel Framing (Max. JW=8") 2-hour CP 672 FC
CFS-SP WB
CEJ245P_021312.pdf Concrete Panels with Steel Framing (Max. JW=8") 2-hour CP 672 FC
CFS-SP WB
CEJ246P_031711.pdf Glass Spandrel Panel and Aluminum Framing 2-hour CP 672 FC
CFS-SP WB
CEJ259P_021312.pdf Gypsum with EIFS Finish and Steel Framing (Max. JW=8") 2-hour CP 672 FC
CFS-SP WB
CEJ260P_112010.pdf Gypsum with Stucco Finish and Steel Framing (Max. JW=8") 2-hour CP 672 FC
CFS-SP WB
CEJ261P_112010.pdf Gypsum with Stone Finish and Steel Framing (Max. JW=8") 2-hour CP 672 FC
CFS-SP WB
CEJ262P_112010.pdf Gypsum with Brick Finish and Steel Framing (Max. JW=8") 2-hour CP 672 FC
CFS-SP WB
CEJ263P_112010.pdf Gypsum with Aluminum or Steel Siding and Steel Framing (Max. JW=8") 2-hour CP 672 FC
CFS-SP WB
CEJ264P_112010.pdf Gypsum with EIFS Finish and Steel Framing (Max. JW=8") 2-hour CP 672 FC
CFS-SP WB
CEJ265P_112010.pdf Gypsum with Aluminum or Steel Siding and Steel Framing (Max. JW=8") 2-hour CP 672 FC
CFS-SP WB
CEJ307P_110610.pdf Glass or Aluminum Spandrel with Aluminum Framing (Max. JW=8") 3-hour CP 672 FC
CFS-SP WB
CEJ308P_110610.pdf Glass Spandrel with I-shaped Aluminum Framing (Max. JW=8") 3-hour CP 672 FC
CFS-SP WB
CEJ309P_102910.pdf Glass Spandrel with Aluminum Framing (Max. JW=8") 1-3/4Hr CP 672 FC
CFS-SP WB
CEJ310P_102910.pdf Glass Spandrel with Aluminum Framing (I-shaped) (Max. JW=8") 1-3/4 hour CP 672 FC
CFS-SP WB
CEJ314P_110610.pdf Gypsum with Brick Finish and Steel Framing (Max. JW=6") 2-3/4 hour CP 672 FC
CFS-SP WB
CEJ 315P.pdf Gypsum with Cementitious Finish and Steel Framing (Max. JW=6") 2-3/4 hour CP 672 FC
CFS-SP WB
CEJ316P_110610.pdf Gypsum with Plaster Finish and Steel Framing (Max. JW=6") 2-3/4 hour CP 672 FC
CFS-SP WB
CEJ400P_110510.pdf GFRC Panels with steel framing (Max. JW=8") 2-hour CP 672 FC
CFS-SP WB
CEJ421P_110510.pdf Gypsum wall with various facades (Max. JW=9", including studs) 2-hour CP 672 FC
CFS-SP WB
CEJ425P_110510.pdf Gypsum wall with various facades. Steel framing starts and stops above and below floor (Max. JW=0") 2-hour CP 672 FC
CFS-SP WB
CEJ526P_110510.pdf Glass Spandrel with Aluminum Framing (vision glass at floor) (Max. JW=6") 1-hour CP 672 FC
CFS-SP WB
CEJ529P_110610.pdf Glass spandrel panel with aluminum framing (Max. JW=2") (25% vertical shear movement) 2-hour CP 672 FC
CFS-SP WB
CWD1001_060410.pdf Tilt-up Concrete Panel Curtain Wall (Max. JW=6") 2-hour CP 672 FC
CFS-SP WB
CWD1003_011314.pdf Tilt-up Concrete Panel Curtain Wall (Max. JW=6") 2-hour CP 604
CFS-SILSL
CWD1015_050813.pdf Glass, Aluminum, or Granite Spandrel with Aluminum Framing (Max. JW=4") 2 Hour CP 672 FC
CFS-SP WB
CWD1018_052413.pdf Tilt-up Concrete Panel Curtain Wall (Max. JW=3") 3 Hour CP 672 FC
CFS-SP WB
CWD2025_011113.pdf Insulated Tilt-up Concrete Panel Curtain Wall (Max. JW=8") 2-hour CP 672 FC
CFS-SP WB
CWD2026_011314.pdf Glass, Aluminum, or Granite Spandrel with Aluminum Framing (Max. JW=8") 2-hour CP 604
CFS-SILSL
CWD2027_011113.pdf Glass, Aluminum, or Granite Spandrel with Aluminum Framing (Max. JW=8") 2-hour CP 672 FC
CFS-SP WB
CWD2046_011014.pdf Glass, Aluminum, or Granite Spandrel with Aluminum Framing (Max. JW=8") 2-hour CP 672 FC
CFS-SP WB
CWS1007_060410.pdf Tilt-Up Concrete Panel Curtain Wall (Max JW = 6") 2-hour CP 672 FC
CFS-SP WB
CWS2027_011314.pdf Glass Spandrel Panel and Aluminum Framing (Max. JW=8") 2-hour CP 604
CFS-SILSL
CWS2028_011113.pdf Glass Spandrel Panel and Aluminum Framing (Max. JW=8") 2-hour CP 672 FC
CFS-SP WB
CWS2029_011314.pdf Aluminum Spandrel Panel and Aluminum Framing (Max. JW=8") 2-hour CP 604
CFS-SILSL
CWS2030_011113.pdf Aluminum Spandrel Panel and Aluminum Framing (Max. JW=8") 2-hour CP 672 FC
CFS-SP WB
CWS2031_011113.pdf Granite Spandrel Panel and Aluminum Framing (Max. JW=8") 2-hour CP 604
CFS-SILSL
CWS2032_011113.pdf Granite Spandrel Panel and Aluminum Framing (Max. JW=8") 2-hour CP 672 FC
CFS-SP WB
CWS2053_011113.pdf Insulated Tilt-up Panel Curtain Wall (Max. JW=6") 2-hour CP 672 FC
CFS-SP WB
HI-BP 120-05_112010.pdf Gypsum with various facades. Steel framing starts and stops above and below floor (Max. JW=0") 2-hour CP 672 FC
CFS-SP WB
HI-BP 150-01_071312.pdf Glass spandrel with aluminum framing (vision glass at floor) (Max. JW=8") 2-1/2 hour CFS-SP WB